CITCABLE: Flexible THV Sheathed Cable
Products Description
·Rated temperature:-40℃ ~ 200℃
·Rated voltage: 600V DC
·Conductor: 0.15mm2 to 10.0mm2 fully annealed stranded copper Per ASTM B-33
Operating temperature range
-160 °C to +260°C for PEEK
-60 °C to +260°C for PTFE/PFA
-60 °C to +200°C for Fluoroelastomer / VITON/XLFE/FKM/THV
-60 °C to +200°C for FEP
-60 °C to +200°C for XL-ETFE
-60 °C to +175°C for ETFE
Application
·Flexibility motor wire cables
·Fan motor cables
·Motor Control cable
·Parameter Matching cable
·Power System in Hybrid Electric Vehicle cable
·EV motor cables
it survives temperatures to 300°C and higher for short periods of time. It is safer in overload conditions, because it will not melt. CITCABLE has a custom motor silicone blocked tin copper conductor to prevent moisture and fluids from wicking through the wiring harness system.
Application
·Flexibility motor wire cables
·Fan motor cables
·Motor Control cable
·Parameter Matching cable
·Power System in Hybrid Electric Vehicle cable
·EV motor cables
Products Description
·Rated temperature:-40℃ ~ 200℃
·Rated voltage: 600V DC
·Conductor: 0.15mm2 to 10.0mm2 fully annealed stranded copper Per ASTM B-33
Operating temperature range
-100 °C to +250°C for PEEK/PTFE/PFA
-60 °C to +200°C for Fluoroelastomer / VITON/XLFE/FKM
-60 °C to +200°C for FEP
-60 °C to +200°C for XL-ETFE
-60 °C to +175°C for ETFE
CITCABLE: 200℃ ARX-9-wire R9-wire Cable
Super Flexiable Super Heat, Oil and Gasoline wire cable they are used for sensor wires that require super heat resistance, and AT mission solenoid wires and injector harnesses that require heat and oil resistance. Some of these wires used as in-tank pump harnesses and level sensors
Products Description
·Rated temperature:-60℃ ~ 200℃ ,T4, T6 rated (3000 hours)
·Rated voltage: 600V DC----1500VDC
·Conductor: 0.25mm2 to 50.0mm2 fully annealed stranded copper Per ASTM B-33
Operating temperature range
-40 °C to +200°C for Fluoroelastomer / VITON/XLFE/FKM/FPM
Extremely Flexible cable
• Excellent resistance to automotive fluids
• Compatible with all harness components
• Light-weight
• Fire safety (VW-1)
• Mechanically tough
• Resistant Hydrofluoric acid
Application
1,Cost-Effective Battery Cables
2, Resistant Acid Battery Cables
3, Battery BMS Cables
4, EV Cable
Super Heat Resistant wire cable for Motor
CITCABLE is a high performance fluid blocking or anti-capillary wire built to handle the high temperature fluid environments in engines and transmissions. It is an irradiation cross-linked fluoropolymer with impressive properties. CIT is extremely fluid resistant even at temperatures up to 150°C 200°C 250°C. It is an excellent, cost effective replacement for TFE, FEP ,Tefzel,TPI.PEI or PEEK insulated wire.>
Flexible XLFE anti-capillary cable
CITCABLE is a high performance fluid blocking or anti-capillary wire built to handle the high temperature fluid environments in engines and transmissions. It is an irradiation cross-linked fluoropolymer with impressive properties. CIT is extremely fluid resistant even at temperatures up to 150°C 200°C 250°C. It is an excellent, cost effective replacement for TFE, FEP ,Tefzel,TPI.PEI or PEE .insulated wire.
Products Description
·Rated temperature:-60℃ ~ 200℃ ,T4, T6 rated (3000 hours)
·Rated voltage: 600V DC----1500VDC
·Conductor: 0.25mm2 to 50.0mm2 fully annealed stranded copper Per ASTM B-33
Operating temperature range
-40 °C to +200°C for Fluoroelastomer / VITON/XLFE/FKM
-60 °C to +200°C for Silicone (VW-1)
Extremely Flexible cable
• Excellent resistance to automotive fluids
• Compatible with all harness components
• Light-weight
• Fire safety (VW-1)
• Mechanically tough
• Resistant Hydrofluoric acid
High Temperature Motor Lead Wire
Motor Lead wire is a high-temperature wire that may be used as motor lead wire for hazardous locations. Depending on its conductor size, this wire can be rated to either 150°C or 200°C, but it has an overall voltage rating of 5000V. It can also be used as a lead wire for electrical equipment in high-temperature environments. Motor Lead Wire wire performs well where flexibility and fire resistance are important
Motor Lead Construction:
Conductor: Stranded tin-plated annealed copper, conforming to ASTM B-33
Insulation: Extruded VITON,PEI,XLFE,PEEK, silicone rubber with overall, non-fraying, fiberglass braid with a glossy high-temperature saturant finish.
Wire Ratings:
Conductors with 26 AWG and 6AWG rated 150°C 200°C 260°C ,300°C non-UL
Oil cooled motor lead wire cable
Specifications Construction:
Conductor: Stranded tin-plated annealed copper, conforming to ASTM B-33
Insulation: Extruded VITON,FKM,XLFE rubber with overall, non-fraying, fiberglass braid with a glossy high-temperature saturant finish.
Wire Ratings:
Conductors with 4 AWG strands or larger are rated at 200°C and those with 6 AWG strands or smaller are rated at 150°C;
6 AWG and 8 AWG rated 150°C 200°C ,230°C
Motor / Pump Winding Cable>
CITCABLE: Flexible THV Sheathed Cable
Products Description
·Rated temperature:-40℃ ~ 200℃
·Rated voltage: 600V DC
·Conductor: 0.15mm2 to 10.0mm2 fully annealed stranded copper Per ASTM B-33
Operating temperature range
-160 °C to +260°C for PEEK
-60 °C to +260°C for PTFE/PFA
-60 °C to +200°C for Fluoroelastomer / VITON/XLFE/FKM/THV
-60 °C to +200°C for FEP
-60 °C to +200°C for XL-ETFE
-60 °C to +175°C for ETFE
Application
·Flexibility motor wire cables
·Fan motor cables
·Motor Control cable
·Parameter Matching cable
·Power System in Hybrid Electric Vehicle cable
·EV motor cables